Products
Outdoor Three-Phase Oil-Immersed Combined Instrument Transformer
  • Outdoor Three-Phase Oil-Immersed Combined Instrument TransformerOutdoor Three-Phase Oil-Immersed Combined Instrument Transformer

Outdoor Three-Phase Oil-Immersed Combined Instrument Transformer

Ceho is a reliable supplier of Outdoor Three-Phase Oil-Immersed Combined Instrument Transformer. Combined Interchange Inductors (CITs) integrate current transformers (CTs) and voltage transformers (VTs) into a compact unit. The "three-phase" design can handle all three-phase voltages simultaneously, while "oil-immersed" indicates that the core and windings are submerged in insulating oil within a sealed tank. This product is meticulously designed to withstand harsh environmental conditions, making it a durable choice for outdoor substation applications.

Ceho, as a professional R&D and manufacturing factory of Outdoor Three-Phase Oil-Immersed Combined Instrument Transformer in China, specializes in mass production, strict ISO quality control and OEM/ODM service. These transformers remain a critical and reliable component in global power infrastructures. T superior heat dissipation, proven high-voltage performance, and cost-effectiveness in large-scale projects ensure its continued importance.


For engineers and power companies, selecting this technology is a strategic decision, particularly for high-voltage applications where overload capacity is critical, and it enables the implementation of necessary environmental safety measures and maintenance procedures.

JLXZY Type description

1. Rated voltage: 33 kV, 11 kV, 6 kV

2. Accuracy level: 0.5 and 0.2 levels, 0.5S and 0.2S level

3. Rated voltage ratio: 33000/110 V, 11000/110 V, 6000/110 V Current ratio: primary current: 2.5, 5, 7. 5, 10, 15, 20, 30, 40, 50, 75, 100...A and other specifications.

The secondary current 5A.

4. Double variable ratio current specification: the double variable ratio current porcelain bottle has an indication of current ratio ratio sign P1, P2 is a large curent.

The current ratio connection method should be selected according to the maximum capacity of the corresponding transformer. Ratio P1, P3 are small current ratio


 JLXZY Main Technical Parameters

 

 

 

 

 

 

 

Some technical parameters of JLXZY voltage part

 

 

 

 

 

 

 

Rated primary voltage
(kV)

Max primary voltage
(kV)

Rated secondary voltage
(kV)

Rated load and accuracy

Max capacity
(VA)

Primary power frequency
withstand voltage(kV)

Rated insulation
level

0.2

0.5

1

3

3.5

100

15

25

80

320

25

3.6/25/40

6

6.9

100

15

25

80

320

32

7.2/32/60

11

11.5

100

15

25

80

60

38

12/42/75

33

40.5

100

40

80

150

1000

80

41/95/200

Some technical parameters of JLXZY current part

 

 

 

 

 

Rated primary current
(A)

Rated secondary current
(A)

Rated burden(VA)

FS time

Time of 1s thermal
stability current

Time of rated dynamic
stability current

0.2S

0.2

0.5S

0.5

Single ratio

0.5.12.5.5.7.5.10.15.20.25
30.40.50.60.75.100.120.150
200.250.300.400.600.800

5

10

10

10

10

10

70

120

Double ratio

2.5-5,5-10,7.5-15,10-20,15-30
20-40,25-50,30-60,50-75,
100-200,150-300,250-500

 

 


Send Inquiry