110kV to 550KV Oil Immersed High Voltage Power Transformer
As a professional high quality CEHO 110kV to 550KV Oil Immersed High Voltage Power Transformer manufacturer,we will offer you the best after-sale service.
Primary Voltage: 110kV or Customizable
Secondary Voltage: 6.3kV,10.5kV,6.6kV,11kV,33kV,69kV or Customizable
CONNECTION TYPE: YNd11/YNyn0 or others
Standards: IEC, ANSI/IEEE, CSA/CAN
Power Rating: 500 kVA-200 MVA
Certificate: ISO9001, ISO14001, CE, SGS,UL
The 110kV to 550KV Oil Immersed High Voltage Power Transformer is applicable to the renovation of local public power grids and energy-saving applications in various enterprises. It was optimized and designed by R&D engineers using the latest technologies such as insulation, electromagnetic force, and temperature field, as well as new fundamental research achievements. It is the best choice for power transformers.
Technical Characteristics
Place of Origin
ZHEJIANG, China
Brand Name
CEHO
Coil Number
2 winding
Use
power
Output Voltage
or others, 6.3kv, 10.5kv, 6.6kv, 11kv, 33kv, 69kv
Input Voltage
or others, 63kv, 66kv, 69kv, 110kv, 132kv, 138kv, 220kv
Usage
Power
Phase
Three
Coil Structure
TOROIDAL/ PIE COIL
Coil Number
2 winding
Tap Changer
OLTC
Frequency
50Hz/60Hz
Winding material
Copper
Certification
ISO9001:2008 CE
Vector group
Dyn11,Yyn0,Yzn11
Rated capacity
6300KVA to 80000KVA
Standard
IEC60076
Cooling Method
ONAN ONAF
Operating temperature
40 To+180
keywords
oil immersed transformer
Warranty
2 Years
Voltage Level
Rated Capacity
(kva)
HV
(kV)
HV
Tapping Ranges
LV
(kV)
Vector-group
Short -Circuit Impendance
No-load Loss
On-load Loss
No-load
Current
(%)
6300
63
66
69
110
132
138
220
or
other
±8×1.25%
or others
6.3
6.6
10.5
11
33
69
or
others
YNd11
YNyn0
or otheres
10-14
9.4
34
0.63
8000
11.2
40.4
0.63
10000
13.1
47.6
0.75
12500
15.4
56.5
0.53
16000
18.5
69.5
0.49
20000
21.8
84.2
0.49
25000
25.6
99.5
0.4
31500
30.4
120
0.4
40000
36.2
140.3
0.39
50000
42.6
174.3
0.39
63000
52
210
0.39
75000
60
238
0.49
90000
69
274
0.49
120000
85
328
0.46
150000
101
385
0.42
160000
105
404
0.42
180000
115
436
0.42
240000
144
539
0.4
Importance in High Voltage Transmission and Distribution
Why this 110kV to 550kV Oil Immersed High Voltage Power Transformer is important is to mention the efficiency in terms of power transmission.When the voltage rises to 110kV, the loss is minimized when the power is transmitted over a long distance, the current in the conductor is reduced, the resistance loss is reduced, and the efficiency of the whole transmission process is very high.And it can also maintain the voltage in a stable range, if you are worried about voltage fluctuations damage to equipment, can choose our this product to provide protection.
The standard for most of the world's national grids is 110kV, and our transformers meet this standard, are more adaptable, and can be customized to specific voltage requirements and expanded to meet growing demand.Compliant with international standards such as IEC 60076, ANSI/IEEE C57, EN 60076, it is capable of handling high power.
Protection Systems
The protection system of 110kV to 550kV Oil Immersed High Voltage Power Transformer is not a single one, but covers many aspects, from oil temperature monitoring, oil level monitoring, pressure protection, gas monitoring and overcurrent protection.
The oil temperature of transformer oil needs to be monitored. The change of high temperature is a prompt for abnormality and failure. When the system alarm is triggered, it prompts you to take corresponding measures.In addition, regarding the transformer mailbox, the oil level also needs to be noted, low or high is not a good phenomenon, you can use the oil level monitoring system to judge the problem and deal with it.
This aspect of pressure protection is also the monitoring of oil pressure, oil pressure too high will cause equipment leakage or damage.The gas monitoring system is responsible for detecting the content of combustible gases inside.Finally, in order to protect the transformer from overload or short circuit, the overcurrent protection system is designed to trigger the protection action when the current exceeds the set threshold.
For inquiries about power transformer, box-type substation, switchgear or price list, please leave your email to us and we will be in touch within 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy