Products
110kV to 550KV Oil Immersed High Voltage Power Transformer
  • 110kV to 550KV Oil Immersed High Voltage Power Transformer110kV to 550KV Oil Immersed High Voltage Power Transformer

110kV to 550KV Oil Immersed High Voltage Power Transformer

As a professional high quality CEHO 110kV to 550KV Oil Immersed High Voltage Power Transformer manufacturer,we will offer you the best after-sale service.
Primary Voltage: 110kV or Customizable
Secondary Voltage: 6.3kV,10.5kV,6.6kV,11kV,33kV,69kV or Customizable
CONNECTION TYPE: YNd11/YNyn0 or others
Standards: IEC, ANSI/IEEE, CSA/CAN
Power Rating: 500 kVA-200 MVA
Certificate: ISO9001, ISO14001, CE, SGS,UL

The 110kV to 550KV Oil Immersed High Voltage Power Transformer is applicable to the renovation of local public power grids and energy-saving applications in various enterprises. It was optimized and designed by R&D engineers using the latest technologies such as insulation, electromagnetic force, and temperature field, as well as new fundamental research achievements. It is the best choice for power transformers.

Technical Characteristics

Place of Origin

ZHEJIANG, China

Brand Name

CEHO

Coil Number

2 winding

Use

power

Output Voltage

or others, 6.3kv, 10.5kv, 6.6kv, 11kv, 33kv, 69kv

Input Voltage

or others, 63kv, 66kv, 69kv, 110kv, 132kv, 138kv, 220kv

Usage

Power

Phase

Three

Coil Structure

TOROIDAL/ PIE COIL

Coil Number

2 winding

Tap Changer

OLTC

Frequency

50Hz/60Hz

Winding material

Copper

Certification

ISO9001:2008 CE

Vector group

Dyn11,Yyn0,Yzn11

Rated capacity

6300KVA to 80000KVA

Standard

IEC60076

Cooling Method

ONAN ONAF

Operating temperature

40 To+180

keywords

oil immersed transformer

Warranty

2 Years

Voltage Level

Rated Capacity
(kva)

HV
(kV)

HV
Tapping Ranges

LV
(kV)

Vector-group

Short -Circuit Impendance

No-load Loss

On-load Loss

No-load
Current
(%)

6300

63
66
69
110
132
138
220
or
other

±8×1.25%
or others

6.3
6.6
10.5
11
33
69
or
others

YNd11
YNyn0
or otheres

10-14

9.4

34

0.63

8000

11.2

40.4

0.63

10000

13.1

47.6

0.75

12500

15.4

56.5

0.53

16000

18.5

69.5

0.49

20000

21.8

84.2

0.49

25000

25.6

99.5

0.4

31500

30.4

120

0.4

40000

36.2

140.3

0.39

50000

42.6

174.3

0.39

63000

52

210

0.39

75000

60

238

0.49

90000

69

274

0.49

120000

85

328

0.46

150000

101

385

0.42

160000

105

404

0.42

180000

115

436

0.42

240000

144

539

0.4

Importance in High Voltage Transmission and Distribution

Why this 110kV to 550kV Oil Immersed High Voltage Power Transformer is important is to mention the efficiency in terms of power transmission.When the voltage rises to 110kV, the loss is minimized when the power is transmitted over a long distance, the current in the conductor is reduced, the resistance loss is reduced, and the efficiency of the whole transmission process is very high.And it can also maintain the voltage in a stable range, if you are worried about voltage fluctuations damage to equipment, can choose our this product to provide protection.

The standard for most of the world's national grids is 110kV, and our transformers meet this standard, are more adaptable, and can be customized to specific voltage requirements and expanded to meet growing demand.Compliant with international standards such as IEC 60076, ANSI/IEEE C57, EN 60076, it is capable of handling high power.

Protection Systems

The protection system of 110kV to 550kV Oil Immersed High Voltage Power Transformer is not a single one, but covers many aspects, from oil temperature monitoring, oil level monitoring, pressure protection, gas monitoring and overcurrent protection.

The oil temperature of transformer oil needs to be monitored. The change of high temperature is a prompt for abnormality and failure. When the system alarm is triggered, it prompts you to take corresponding measures.In addition, regarding the transformer mailbox, the oil level also needs to be noted, low or high is not a good phenomenon, you can use the oil level monitoring system to judge the problem and deal with it.

This aspect of pressure protection is also the monitoring of oil pressure, oil pressure too high will cause equipment leakage or damage.The gas monitoring system is responsible for detecting the content of combustible gases inside.Finally, in order to protect the transformer from overload or short circuit, the overcurrent protection system is designed to trigger the protection action when the current exceeds the set threshold.



Send Inquiry
Contact Info
For inquiries about power transformer, box-type substation, switchgear or price list, please leave your email to us and we will be in touch within 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept